BackgroundCheck.run
Search For

Gene Ritchey, ~841231 Valerian Ct, Sunnyvale, CA 94086

Gene Ritchey Phones & Addresses

1231 Valerian Ct, Sunnyvale, CA 94086    408-7335858   

Tracy, CA   

Fallon, NV   

1231 Valerian Ct APT 2, Sunnyvale, CA 94086    408-5092025   

Work

Position: Private Household Service Occupations

Education

Degree: High school graduate or higher

Mentions for Gene Ritchey

Business Records

Name / TitleCompany / ClassificationPhones & Addresses
Gene Ritchey
Owner
Gene Ritchey Dr 1231 Valerian Ct, Sunnyvale, CA 94086

Publications

Us Patents

Free-Standing Clear-Span Frame Structure And Components

US Patent:
2005025, Nov 17, 2005
Filed:
Apr 2, 2004
Appl. No.:
10/817587
Inventors:
Gene Ritchey - Sunnyvale CA,
Gary Hicks - Mountain View CA,
Assignee:
Golden Star, Inc. - Reno NV
International Classification:
E04H012/00
US Classification:
052648100
Abstract:
Novel free-standing open-span building frames for building construction and their use. The frames are assembled from base plates, upright posts, post-joist-rafter connectors, and a joist. Each base plate is a steel plate having an upper surface to which is welded the lower end of a steel post connector. The steel plates anchor bolt holes therethrough on each side of the post connector. The building has a steel reinforced concrete foundation with anchor bolts extending through the anchor bolt holes of each base plate, each base plate being secured to the anchor bolts with nuts. Each post has a lower end bolted to the respective steel post connector of the first and second base plate. Each post-joist-rafter connector comprises a post connector, a joist connector and a rafter connector. The first post has an upper end bolted to the post connector of the first post-joist-rafter connector, and the second post has an upper end bolted to the post connector of the second post-joist-rafter connector. The joist has first and second joist ends, the first joist end being bolted to the joist connector of the first post-joist-rafter connector, and the second joist end being bolted to the joist connector of the second post-joist-rafter connector. The frames are free-standing and can be spaced at distances of from 3 to 14 meters per frame.

NOTICE: You may not use BackgroundCheck or the information it provides to make decisions about employment, credit, housing or any other purpose that would require Fair Credit Reporting Act (FCRA) compliance. BackgroundCheck is not a Consumer Reporting Agency (CRA) as defined by the FCRA and does not provide consumer reports.